Skip to content

GLOSSARY OF TERMS

A

Air Gap

The space between the poles of a magnetic system in which the useful magnetic field is present.

Anisotropy

In general, anisotropy expresses the difference in material properties in geometrically different directions. In the case of anisotropic permanent magnets, the amount of energy required to magnetize them differs depending on the direction. This is achieved through the interaction of a strong magnetic field during pressing of the magnet body from ferrite powder or suspension. In the direction of the applied magnetic field, the pressed body can be magnetized more easily and a significantly higher value of remanent magnetic induction Br can also be achieved. The most commonly used types are magnetocrystalline anisotropy and shape anisotropy.

Antiferromagnetism

Elementary domains are also formed here, but with two different sublattices whose magnetic moments are antiparallel, meaning opposite and equal in magnitude. Materials of this type behave as paramagnetic materials (α-Mn, FeO, Fe₂O₃, FeS, CoO).

Application Temperature (Operating Temperature)

The maximum temperature at which a magnet can operate without permanent loss of its magnetic properties.

B

Barium (Ba)

A chemical element of Group II of the periodic table of elements (alkaline earth metals). The most important raw material is barite. In the production of ferrite magnets, barium is added in the form of barium carbonate to ferric oxide, and during calcination the compound BaFe₁₂O₁₉ (barium ferrite) is formed.

C

Calibration

Adjustment and adaptation of magnetic flux to a narrower tolerance. The usual tolerance is approximately ±10%.

Ceramic Permanent Magnets

Magnetically hard ferrites made from ceramic materials, namely barium and strontium ferrites. They are brittle and do not withstand impacts well.

Coercive Magnetic Field Strength (Coercivity)

The unit is kA/m or A/cm. It is the magnetic field strength Hc that causes demagnetization of a magnetized ferromagnetic material, reducing the remanence Br to zero.

Correction Angle

The angle between the operating line and the B-axis in the B = f(H) diagram.

Curie Temperature

The transition temperature at which a ferromagnetic material loses its magnetism (named after Madame Curie). Above this temperature, the ferromagnetic material changes into a paramagnetic material.

D

Demagnetization

The reduction of the remanent magnetic induction Br down to a completely demagnetized state. Methods: 1. Using a direct-current magnetic field with the opposite orientation. 2. Heating to at least the Curie temperature Tc (450 °C for ferrites). 3. Using ionizing radiation. 4. Using a damped alternating magnetic field.

Demagnetization Curve

The part of the hysteresis curve located in the second quadrant of the rectangular coordinate system. The shape of the demagnetization curve and its final values Br (remanence) and Hc (coercivity) determine the essential magnetic values of a permanent magnet.

Demagnetizing Factors (N)

When the operating point of a magnet is connected to the origin of the coordinate system, a correction line is obtained. The angle between the second ordinate (B-axis) and the correction line is the correction angle. N is dimensionless and has a value between 0 (Br, closed circuit) and 1 (completely open circuit).

Density - Specific Weight

A physical quantity expressed in [g/cm³] or [kg/dm³].

Dimensional Ratio h : D

The ratio of height to diameter in cylindrical magnets, determining the position of the operating point.

Distortion (Correction)

A change in the slope of the operating line resulting from a change in the geometry of the magnetic circuit.

E

Energy Density (B · H)

The product of the magnetic induction B and the coercive magnetic field strength H. It is represented as the inscribed rectangle below the demagnetization curve.

F

Ferromagnetism

It occurs in materials where a certain relationship exists between the interatomic distance and the atomic radius (Fe, Co, Ni, AlNiCo). Neighboring atoms align parallel to each other and form domains. Cubic ferrites are magnetically soft, while hexagonal ferrites are magnetically hard.

Fluxmeter

An instrument used to measure magnetic flux.

G

G - Gauss

A unit of magnetic induction in the CGS system of units. Named after Friedrich Gauss. Conversion: 1 G = 10⁻⁴ T, 1 T = 1000 mT, 1 mT = 10 G.

H

H - Magnetic Field Strength

A fundamental physical quantity describing the force effects of a magnetic field.

Hysteresis

The closed area defined by separate magnetization and demagnetization curves, usually in the saturation region (the so-called limiting hysteresis curve).

Hysteresis Loop

Shows the relationship between magnetic induction and magnetic field strength H, i.e. J = f(H) or B = f(H).

I

Irreversible

An irreversible or non-repeatable process. During an irreversible change, for example due to temperature, the values of magnetic quantities do not return to their original values after returning to the original conditions.

Isostatic

Pressing powder in an elastic mould under uniform pressure in a liquid at pressures of several thousand bar.

Isotropy

Homogeneity of physical, in this case magnetic, properties in all directions.

L

Lines of Force

Imaginary lines representing the direction and strength of a magnetic field.

M

Magnetic Circuit

The path through which magnetic flux passes. It consists of a permanent magnet, pole pieces, an air gap and stray magnetic fields.

Magnetic Flux (Φ)

The flow of a magnetic field through an area. It is the product of magnetic induction and area (Φ = B · S). The SI unit is 1 Weber (Wb) = 1 Vs.

Magnetic Flux Measurement

It is performed using an instrument called a fluxmeter.

Magnetic Induction (B)

The density of magnetic lines of force. The formula is: B (T) = magnetic flux Φ (Wb) / cross-sectional area A (m²). The unit in the SI system is the tesla (T), formerly the gauss (G).

Magnetic Point (Operating Point)

A point on the demagnetization curve whose B and H values are decisive for calculating a magnetic circuit.

Magnetic Pole

The area on a source of a magnetic field from which magnetic flux emerges (north pole) or into which it enters (south pole).

Magnetic Polarization (J)

The difference between the magnetic induction B in a ferromagnetic material and the induction in vacuum B₀.

Magnetic Susceptibility (χ)

A measure of the magnetization of a material in an external magnetic field.

Magnetically Hard Ferrite

Barium or strontium ferrite with the chemical composition MeO·6Fe₂O₃ (hexaferrite).

Magnetism

A physical phenomenon associated with the movement of electric charges and the spin of electrons, which create elementary magnetic moments.

Magnetization

The process of magnetizing a previously non-magnetic material by applying an external magnetic field.

Maxwell

A unit of magnetic flux in the CGS system (1 Maxwell = 10⁻⁸ Wb).

O

Oe - Oersted

A unit of magnetic field strength in the CGS system. Conversion: 1 Oe = 0.796 A/cm.

Operating Line

The line connecting the operating point with the origin of the coordinate system in the B = f(H) graph.

Operating Point

A point on the demagnetization curve whose B and H values are decisive for calculating a magnetic circuit.

P

Paramagnetism

A property of materials whose atoms have a permanent magnetic moment but do not interact with each other. An external magnetic field slightly increases their magnetization.

Permanent Magnet

A magnet that retains its magnetic field for a long period of time after being magnetized.

Permeability (μ)

The magnetic conductivity or permeability of a material. The ratio of magnetic induction B to magnetic field strength H.

Permeability of Vacuum (μ₀)

A physical constant: μ₀ = 1.256 × 10⁻⁶ H/m = 1.256 mT/(kA/m).

Preferred Magnetization Direction

The direction in which a permanent magnet achieves its best magnetic parameters.

R

Remanent Magnetic Induction (Br)

The residual magnetic induction remaining in a material after the external magnetic field has been removed. It is expressed in Tesla (T).

Reversible

A reversible process. It means that the properties return to their original values after the external influence, such as temperature, has ceased.

Reversible Permeability (μrev)

The reversible permeability representing the slope of the minor or repeated magnetization curve.

S

Saturation

A state in which increasing the external magnetic field no longer increases the magnetic polarization of the material (saturated polarization).

Sintering

Thermal treatment (sintering) at high temperatures during which the pressed powder is strengthened and homogenized.

Stabilization

Thermal or magnetic treatment of a magnet intended to prevent future spontaneous changes in magnetic flux.

Strontium (Sr)

An element added to hard ferrites to achieve high coercivity.

T

T - Tesla

A unit of magnetic induction in the SI system (1 T = 1 Wb/m² = 10,000 Gauss).

Temperature Coefficient

Indicates the percentage change in remanence or coercivity per 1 °C change in temperature.

Tungsten (W)

A metallic element with high density and the highest melting point of all metals. It is used in demanding industrial applications and recycling.

U

Useful Magnetic Flux

The part of the magnetic flux linking the working air gap of the magnetic circuit.

W

W - Weber

A unit of magnetic flux in the SI system (1 Wb = 1 Vs = 10⁸ Maxwell).

+420 554 774 253